services: Add apcupsd-service-type.
* gnu/services/power.scm: New file. * gnu/local.mk (GNU_SYSTEM_MODULES): Add it. * doc/guix.texi (Power Management Services): Document service and data types. Change-Id: If205d19bea1d20a99309626e28521a2d6fe6702f Signed-off-by: Maxim Cournoyer <maxim.cournoyer@gmail.com> Reviewed-by: Maxim Cournoyer <maxim.cournoyer@gmail.com>
This commit is contained in:
parent
4319fb1aa9
commit
d0e46a0003
3 changed files with 1049 additions and 3 deletions
382
doc/guix.texi
382
doc/guix.texi
|
@ -123,7 +123,7 @@ Copyright @copyright{} 2023 Foundation Devices, Inc.@*
|
|||
Copyright @copyright{} 2023 Thomas Ieong@*
|
||||
Copyright @copyright{} 2023 Saku Laesvuori@*
|
||||
Copyright @copyright{} 2023 Graham James Addis@*
|
||||
Copyright @copyright{} 2023, 2024 Tomas Volf@*
|
||||
Copyright @copyright{} 2023-2025 Tomas Volf@*
|
||||
Copyright @copyright{} 2024, 2025 Herman Rimm@*
|
||||
Copyright @copyright{} 2024 Matthew Trzcinski@*
|
||||
Copyright @copyright{} 2024 Richard Sent@*
|
||||
|
@ -422,7 +422,7 @@ Services
|
|||
* Network File System:: NFS related services.
|
||||
* Samba Services:: Samba services.
|
||||
* Continuous Integration:: Cuirass and Laminar services.
|
||||
* Power Management Services:: Extending battery life.
|
||||
* Power Management Services:: Extending battery life, etc.
|
||||
* Audio Services:: The MPD.
|
||||
* Virtualization Services:: Virtualization services.
|
||||
* Version Control Services:: Providing remote access to Git repositories.
|
||||
|
@ -19287,7 +19287,7 @@ declaration.
|
|||
* Network File System:: NFS related services.
|
||||
* Samba Services:: Samba services.
|
||||
* Continuous Integration:: Cuirass and Laminar services.
|
||||
* Power Management Services:: Extending battery life.
|
||||
* Power Management Services:: Extending battery life, etc.
|
||||
* Audio Services:: The MPD.
|
||||
* Virtualization Services:: Virtualization services.
|
||||
* Version Control Services:: Providing remote access to Git repositories.
|
||||
|
@ -36891,6 +36891,382 @@ packages linux)} module
|
|||
@end table
|
||||
@end deftp
|
||||
|
||||
The @code{(gnu services power)} module provides a service definition for
|
||||
@uref{http://www.apcupsd.org/, apcupsd}, a utility to interact with
|
||||
@acronym{APC, APC by Schneider Electric or formerly American Power
|
||||
Conversion Corporation} @acronym{UPS, Uninterruptible Power Supply}
|
||||
devices. Apcupsd also works with some @acronym{OEM, Original Equipment
|
||||
Manufacturer}-branded products manufactured by APC.
|
||||
|
||||
@defvar apcupsd-service-type
|
||||
The service type for apcupsd. For USB UPSes no configuration is
|
||||
necessary, however tweaking some fields to better suit your needs might
|
||||
be desirable. The defaults are taken from the upstream configuration
|
||||
and they are not very conservative (for example, the default
|
||||
@code{battery-level} of 5% may be considered too low by some).
|
||||
|
||||
The default event handlers do send emails, read more in
|
||||
@ref{apcupsd-event-handlers}.
|
||||
|
||||
@lisp
|
||||
(service apcupsd-service-type)
|
||||
@end lisp
|
||||
@end defvar
|
||||
|
||||
@deftp {Data Type} apcupsd-configuration
|
||||
|
||||
Available @code{apcupsd-configuration} fields are:
|
||||
|
||||
@table @asis
|
||||
@item @code{apcupsd} (default: @code{apcupsd}) (type: package)
|
||||
The @code{apcupsd} package to use.
|
||||
|
||||
@item @code{shepherd-service-name} (default: @code{apcupsd}) (type: symbol)
|
||||
The name of the shepherd service. You can add the service multiple
|
||||
times with different names to manage multiple UPSes.
|
||||
|
||||
@item @code{auto-start?} (default: @code{#t}) (type: boolean)
|
||||
Should the shepherd service auto-start?
|
||||
|
||||
@item @code{pid-file} (default: @code{"/var/run/apcupsd.pid"}) (type: string)
|
||||
The file name of the pid file.
|
||||
|
||||
@item @code{debug-level} (default: @code{0}) (type: integer)
|
||||
The logging verbosity. Bigger number means more logs. The source code
|
||||
uses up to @code{300} as debug level value, so a value of @code{999}
|
||||
seems reasonable to enable all the logs.
|
||||
|
||||
@item @code{run-dir} (default: @code{"/var/run/apcupsd"}) (type: string)
|
||||
The directory containing runtime information. You need to change this
|
||||
if you desire to run multiple instances of the daemon.
|
||||
|
||||
@item @code{name} (type: maybe-string)
|
||||
Use this to give your UPS a name in log files and such. This is
|
||||
particularly useful if you have multiple UPSes. This does not set the
|
||||
EEPROM. It should be 8 characters or less.
|
||||
|
||||
@item @code{cable} (default: @code{usb}) (type: enum-cable)
|
||||
The type of a cable connecting the UPS to your computer. Possible
|
||||
generic choices are @code{'simple}, @code{'smart}, @code{'ether} and
|
||||
@code{'usb}.
|
||||
|
||||
Alternatively, a specific cable model number may be used:
|
||||
@code{'940-0119A}, @code{'940-0127A}, @code{'940-0128A},
|
||||
@code{'940-0020B}, @code{'940-0020C}, @code{'940-0023A},
|
||||
@code{'940-0024B}, @code{'940-0024C}, @code{'940-1524C},
|
||||
@code{'940-0024G}, @code{'940-0095A}, @code{'940-0095B},
|
||||
@code{'940-0095C}, @code{'940-0625A}, @code{'M-04-02-2000}.
|
||||
|
||||
@item @code{type} (default: @code{usb}) (type: enum-type)
|
||||
The type of the UPS you have.
|
||||
|
||||
@table @code
|
||||
@item apcsmart
|
||||
Newer serial character device, appropriate for SmartUPS models using a
|
||||
serial cable (not an USB).
|
||||
|
||||
@item usb
|
||||
Most new UPSes are an USB.
|
||||
|
||||
@item net
|
||||
Network link to a master apcupsd through apcupsd's Network Information
|
||||
Server. This is used if the UPS powering your computer is connected to
|
||||
a different computer for monitoring.
|
||||
|
||||
@item snmp
|
||||
SNMP network link to an SNMP-enabled UPS device.
|
||||
|
||||
@item netsnmp
|
||||
Same as the SNMP above but requires use of the net-snmp library. Unless
|
||||
you have a specific need for this old driver, you should use the
|
||||
@code{'snmp} instead.
|
||||
|
||||
@item dumb
|
||||
An old serial character device for use with simple-signaling UPSes.
|
||||
|
||||
@item pcnet
|
||||
A PowerChute Network Shutdown protocol which can be used as an
|
||||
alternative to an SNMP with the AP9617 family of smart slot cards.
|
||||
|
||||
@item modbus
|
||||
A serial device for use with newest SmartUPS models supporting the
|
||||
MODBUS protocol.
|
||||
|
||||
@end table
|
||||
|
||||
@item @code{device} (default: @code{""}) (type: string)
|
||||
For USB UPSes, usually you want to set this to an empty string (the
|
||||
default). For other UPS types, you must specify an appropriate port or
|
||||
address.
|
||||
|
||||
@table @code
|
||||
@item apcsmart
|
||||
Set to the appropriate @file{/dev/tty**} device.
|
||||
|
||||
@item usb
|
||||
A null string setting enables auto-detection, which is the best choice
|
||||
for most installations.
|
||||
|
||||
@item net
|
||||
Set to @code{@var{hostname}:@var{port}}.
|
||||
|
||||
@item snmp
|
||||
Set to @code{@var{hostname}:@var{port}:@var{vendor}:@var{community}}.
|
||||
The @var{hostname} is the ip address or hostname of the UPS on the
|
||||
network. The @var{vendor} can be can be "APC" or "APC_NOTRAP".
|
||||
"APC_NOTRAP" will disable SNMP trap catching; you usually want "APC".
|
||||
The @var{port} is usually 161. The @var{community} is usually
|
||||
"private".
|
||||
|
||||
@item netsnmp
|
||||
Same as the @code{'snmp}.
|
||||
|
||||
@item dumb
|
||||
Set to the appropriate @file{/dev/tty**} device.
|
||||
|
||||
@item pcnet
|
||||
Set to @code{@var{ipaddr}:@var{username}:@var{passphrase}:@var{port}}.
|
||||
The @var{ipaddr} is the IP address of the UPS management card. The
|
||||
@var{username} and the @var{passphrase} are the credentials for which
|
||||
the card has been configured. The @var{port} is the port number on
|
||||
which to listen for messages from the UPS, normally 3052. If this
|
||||
parameter is empty or missing, the default of 3052 will be used.
|
||||
|
||||
@item modbus
|
||||
Set to the appropriate @file{/dev/tty**} device. You can also leave it
|
||||
empty for MODBUS over USB or set to the serial number of the UPS.
|
||||
|
||||
@end table
|
||||
|
||||
@item @code{poll-time} (default: @code{60}) (type: integer)
|
||||
The interval (in seconds) at which apcupsd polls the UPS for status.
|
||||
This setting applies both to directly-attached UPSes (apcsmart, usb,
|
||||
dumb) and networked UPSes (net, snmp). Lowering this setting will
|
||||
improve the apcupsd's responsiveness to certain events at the cost of
|
||||
higher CPU utilization.
|
||||
|
||||
@item @code{on-batery-delay} (default: @code{6}) (type: integer)
|
||||
The time in seconds from when a power failure is detected until we react
|
||||
to it with an onbattery event. The @code{'powerout} event will be
|
||||
triggered immediately when a power failure is detected. However, the
|
||||
@code{'onbattery} event will be trigger only after this delay.
|
||||
|
||||
@item @code{battery-level} (default: @code{5}) (type: integer)
|
||||
If during a power failure, the remaining battery percentage (as reported
|
||||
by the UPS) is below or equal to this value, the apcupsd will initiate a
|
||||
system shutdown.
|
||||
|
||||
@quotation Note
|
||||
@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work
|
||||
in a conjunction, so the first that occurs will cause the initation of a
|
||||
shutdown.
|
||||
@end quotation
|
||||
|
||||
@item @code{remaining-minutes} (default: @code{3}) (type: integer)
|
||||
If during a power failure, the remaining runtime in minutes (as
|
||||
calculated internally by the UPS) is below or equal to this value,
|
||||
apcupsd will initiate a system shutdown.
|
||||
|
||||
@quotation Note
|
||||
@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work
|
||||
in a conjunction, so the first that occurs will cause the initation of a
|
||||
shutdown.
|
||||
@end quotation
|
||||
|
||||
@item @code{timeout} (default: @code{0}) (type: integer)
|
||||
If during a power failure, the UPS has run on batteries for this many
|
||||
seconds or longer, apcupsd will initiate a system shutdown. The value
|
||||
of 0 disables this timer.
|
||||
|
||||
@quotation Note
|
||||
@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work
|
||||
in a conjunction, so the first that occurs will cause the initation of a
|
||||
shutdown.
|
||||
@end quotation
|
||||
|
||||
@item @code{annoy-interval} (default: @code{300}) (type: integer)
|
||||
The time in seconds between annoying users (via the @code{'annoyme}
|
||||
event) to sign off prior to system shutdown. 0 disables.
|
||||
|
||||
@item @code{annoy-delay} (default: @code{60}) (type: integer)
|
||||
The initial delay in seconds after a power failure before warning users
|
||||
to get off the system.
|
||||
|
||||
@item @code{no-logon} (default: @code{disable}) (type: enum-no-logon)
|
||||
The condition which determines when users are prevented from logging in
|
||||
during a power failure.
|
||||
|
||||
@item @code{kill-delay} (default: @code{0}) (type: integer)
|
||||
If this is non-zero, the apcupsd will continue running after a shutdown
|
||||
has been requested, and after the specified time in seconds attempt to
|
||||
kill the power. This is for use on systems where apcupsd cannot regain
|
||||
control after a shutdown.
|
||||
|
||||
@item @code{net-server} (default: @code{#f}) (type: boolean)
|
||||
If enabled, a network information server process will be started.
|
||||
|
||||
@item @code{net-server-ip} (default: @code{"127.0.0.1"}) (type: string)
|
||||
An IP address on which the NIS server will listen for incoming
|
||||
connections.
|
||||
|
||||
@item @code{net-server-port} (default: @code{3551}) (type: integer)
|
||||
An IP port on which the NIS server will listen for incoming connections.
|
||||
|
||||
@item @code{net-server-events-file} (type: maybe-string)
|
||||
If you want the last few EVENTS to be available over the network by the
|
||||
network information server, you must set this to a file name.
|
||||
|
||||
@item @code{net-server-events-file-max-size} (default: @code{10}) (type: integer)
|
||||
The maximum size of the events file in kilobytes.
|
||||
|
||||
@item @code{class} (default: @code{standalone}) (type: enum-class)
|
||||
Normally standalone unless you share an UPS using an APC ShareUPS card.
|
||||
|
||||
@item @code{mode} (default: @code{disable}) (type: enum-mode)
|
||||
Normally disable unless you share an UPS using an APC ShareUPS card.
|
||||
|
||||
@item @code{stat-time} (default: @code{0}) (type: integer)
|
||||
The time interval in seconds between writing the status file, 0
|
||||
disables.
|
||||
|
||||
@item @code{log-stats} (default: @code{#f}) (type: boolean)
|
||||
Also write the stats as a logs. This generates a lot of output.
|
||||
|
||||
@item @code{data-time} (default: @code{0}) (type: integer)
|
||||
The time interval in seconds between writing the data records to the log
|
||||
file, 0 disables.
|
||||
|
||||
@item @code{facility} (type: maybe-string)
|
||||
The logging facility for the syslog.
|
||||
|
||||
@item @code{event-handlers} (type: apcupsd-event-handlers)
|
||||
Handlers for events produced by apcupsd.
|
||||
|
||||
@end table
|
||||
@end deftp
|
||||
|
||||
@anchor{apcupsd-event-handlers}
|
||||
@deftp {Data Type} apcupsd-event-handlers
|
||||
|
||||
For a description of the events please refer to @samp{man 8 apccontrol}.
|
||||
|
||||
Each handler shall be a gexp. It is spliced into the control script for
|
||||
the daemon. In addition to the standard Guile programming environment,
|
||||
the following procedures and variables are also available:
|
||||
|
||||
@table @code
|
||||
@item conf
|
||||
Variable containing the file name of the configuration file.
|
||||
|
||||
@item powerfail-file
|
||||
Variable containing the file name of the powerfail file.
|
||||
|
||||
@item cmd
|
||||
The event currently being handled.
|
||||
|
||||
@item name
|
||||
The name of the UPS as specified in the configuration file.
|
||||
|
||||
@item connected?
|
||||
Is @code{#t} if @command{apcupsd} is connected to the UPS via a serial
|
||||
port (or a USB port). In most configurations, this will be the case.
|
||||
In the case of a Slave machine where apcupsd is not directly connected
|
||||
to the UPS, this value will be @code{#f}.
|
||||
|
||||
@item powered?
|
||||
Is @code{#t} if the computer on which @command{apcupsd} is running is
|
||||
powered by the UPS and @code{#f} if not. At the moment, this value is
|
||||
unimplemented and always @code{#f}.
|
||||
|
||||
@item (err @var{fmt} @var{args...})
|
||||
Wrapper around @code{format} outputting to @code{(current-error-port)}.
|
||||
|
||||
@item (wall @var{fmt} @var{args...})
|
||||
Wrapper around @code{format} outputting via @command{wall}.
|
||||
|
||||
@item (apcupsd @var{args...})
|
||||
Call @command{apcupsd} while passing the correct configuration file and
|
||||
all the arguments.
|
||||
|
||||
@item (mail-to-root @var{subject} @var{body})
|
||||
Send an email to the local administrator. This procedure assumes the
|
||||
@command{sendmail} is located at @command{/run/privileged/bin/sendmail}
|
||||
(as would be the case with @code{opensmtpd-service-type}).
|
||||
|
||||
@end table
|
||||
|
||||
Available @code{apcupsd-event-handlers} fields are:
|
||||
|
||||
@table @asis
|
||||
@item @code{modules} (type: gexp)
|
||||
Additional modules to import into the generated handler script.
|
||||
|
||||
@item @code{killpower} (type: gexp)
|
||||
The handler for the killpower event.
|
||||
|
||||
@item @code{commfailure} (type: gexp)
|
||||
The handler for the commfailure event.
|
||||
|
||||
@item @code{commok} (type: gexp)
|
||||
The handler for the commfailure event.
|
||||
|
||||
@item @code{powerout} (type: gexp)
|
||||
The handler for the powerout event.
|
||||
|
||||
@item @code{onbattery} (type: gexp)
|
||||
The handler for the onbattery event.
|
||||
|
||||
@item @code{offbattery} (type: gexp)
|
||||
The handler for the offbattery event.
|
||||
|
||||
@item @code{mainsback} (type: gexp)
|
||||
The handler for the mainsback event.
|
||||
|
||||
@item @code{failing} (type: gexp)
|
||||
The handler for the failing event.
|
||||
|
||||
@item @code{timeout} (type: gexp)
|
||||
The handler for the timeout event.
|
||||
|
||||
@item @code{loadlimit} (type: gexp)
|
||||
The handler for the loadlimit event.
|
||||
|
||||
@item @code{runlimit} (type: gexp)
|
||||
The handler for the runlimit event.
|
||||
|
||||
@item @code{doreboot} (type: gexp)
|
||||
The handler for the doreboot event.
|
||||
|
||||
@item @code{doshutdown} (type: gexp)
|
||||
The handler for the doshutdown event.
|
||||
|
||||
@item @code{annoyme} (type: gexp)
|
||||
The handler for the annoyme event.
|
||||
|
||||
@item @code{emergency} (type: gexp)
|
||||
The handler for the emergency event.
|
||||
|
||||
@item @code{changeme} (type: gexp)
|
||||
The handler for the changeme event.
|
||||
|
||||
@item @code{remotedown} (type: gexp)
|
||||
The handler for the remotedown event.
|
||||
|
||||
@item @code{startselftest} (type: gexp)
|
||||
The handler for the startselftest event.
|
||||
|
||||
@item @code{endselftest} (type: gexp)
|
||||
The handler for the endselftest event.
|
||||
|
||||
@item @code{battdetach} (type: gexp)
|
||||
The handler for the battdetach event.
|
||||
|
||||
@item @code{battattach} (type: gexp)
|
||||
The handler for the battattach event.
|
||||
|
||||
@end table
|
||||
@end deftp
|
||||
|
||||
@node Audio Services
|
||||
@subsection Audio Services
|
||||
|
||||
|
|
|
@ -765,6 +765,7 @@ GNU_SYSTEM_MODULES = \
|
|||
%D%/services/nix.scm \
|
||||
%D%/services/nfs.scm \
|
||||
%D%/services/pam-mount.scm \
|
||||
%D%/services/power.scm \
|
||||
%D%/services/science.scm \
|
||||
%D%/services/security.scm \
|
||||
%D%/services/security-token.scm \
|
||||
|
|
669
gnu/services/power.scm
Normal file
669
gnu/services/power.scm
Normal file
|
@ -0,0 +1,669 @@
|
|||
;;; Copyright © 2025 Tomas Volf <~@wolfsden.cz>
|
||||
|
||||
;;;; Commentary:
|
||||
|
||||
;;; Power-related services.
|
||||
|
||||
;;;; Code:
|
||||
|
||||
(define-module (gnu services power)
|
||||
#:use-module (gnu)
|
||||
#:use-module (gnu packages admin)
|
||||
#:use-module (gnu packages linux)
|
||||
#:use-module (gnu packages power)
|
||||
#:use-module (gnu services configuration)
|
||||
#:use-module (gnu services shepherd)
|
||||
#:use-module (gnu services)
|
||||
#:use-module (guix packages)
|
||||
#:use-module (guix records)
|
||||
#:use-module (ice-9 match)
|
||||
#:use-module (srfi srfi-1)
|
||||
#:use-module (srfi srfi-26)
|
||||
#:export (apcupsd-service-type
|
||||
|
||||
apcupsd-configuration
|
||||
apcupsd-configuration-apcupsd
|
||||
apcupsd-configuration-shepherd-service-name
|
||||
apcupsd-configuration-auto-start?
|
||||
apcupsd-configuration-pid-file
|
||||
apcupsd-configuration-debug-level
|
||||
apcupsd-configuration-run-dir
|
||||
apcupsd-configuration-name
|
||||
apcupsd-configuration-cable
|
||||
apcupsd-configuration-type
|
||||
apcupsd-configuration-device
|
||||
apcupsd-configuration-poll-time
|
||||
apcupsd-configuration-on-batery-delay
|
||||
apcupsd-configuration-battery-level
|
||||
apcupsd-configuration-remaining-minutes
|
||||
apcupsd-configuration-timeout
|
||||
apcupsd-configuration-annoy-interval
|
||||
apcupsd-configuration-annoy-delay
|
||||
apcupsd-configuration-no-logon
|
||||
apcupsd-configuration-kill-delay
|
||||
apcupsd-configuration-net-server
|
||||
apcupsd-configuration-net-server-ip
|
||||
apcupsd-configuration-net-server-port
|
||||
apcupsd-configuration-net-server-events-file
|
||||
apcupsd-configuration-net-server-events-file-max-size
|
||||
apcupsd-configuration-class
|
||||
apcupsd-configuration-mode
|
||||
apcupsd-configuration-stat-time
|
||||
apcupsd-configuration-log-stats
|
||||
apcupsd-configuration-data-time
|
||||
apcupsd-configuration-facility
|
||||
apcupsd-configuration-event-handlers
|
||||
|
||||
apcupsd-event-handlers
|
||||
apcupsd-event-handlers-modules
|
||||
apcupsd-event-handlers-annoyme
|
||||
apcupsd-event-handlers-battattach
|
||||
apcupsd-event-handlers-battdetach
|
||||
apcupsd-event-handlers-changeme
|
||||
apcupsd-event-handlers-commfailure
|
||||
apcupsd-event-handlers-commok
|
||||
apcupsd-event-handlers-doreboot
|
||||
apcupsd-event-handlers-doshutdown
|
||||
apcupsd-event-handlers-emergency
|
||||
apcupsd-event-handlers-endselftest
|
||||
apcupsd-event-handlers-failing
|
||||
apcupsd-event-handlers-killpower
|
||||
apcupsd-event-handlers-loadlimit
|
||||
apcupsd-event-handlers-mainsback
|
||||
apcupsd-event-handlers-offbattery
|
||||
apcupsd-event-handlers-onbattery
|
||||
apcupsd-event-handlers-powerout
|
||||
apcupsd-event-handlers-remotedown
|
||||
apcupsd-event-handlers-runlimit
|
||||
apcupsd-event-handlers-startselftest
|
||||
apcupsd-event-handlers-timeout))
|
||||
|
||||
(define-configuration/no-serialization apcupsd-event-handlers
|
||||
(modules
|
||||
(gexp #~())
|
||||
"Additional modules to import into the generated handler script.")
|
||||
(killpower
|
||||
(gexp
|
||||
#~((wall "Apccontrol doing: apcupsd --killpower on UPS ~a" name)
|
||||
(sleep 10)
|
||||
(apcupsd "--killpower")
|
||||
(wall "Apccontrol has done: apcupsd --killpower on UPS ~a" name)))
|
||||
"The handler for the killpower event.")
|
||||
(commfailure
|
||||
(gexp
|
||||
#~((let ((msg (format #f "~a Communications with UPS ~a lost."
|
||||
(gethostname) name)))
|
||||
(mail-to-root msg msg))
|
||||
(wall "Warning: communications lost with UPS ~a" name)))
|
||||
"The handler for the commfailure event.")
|
||||
(commok
|
||||
(gexp
|
||||
#~((let ((msg (format #f "~a Communications with UPS ~a restored."
|
||||
(gethostname) name)))
|
||||
(mail-to-root msg msg))
|
||||
(wall "Communications restored with UPS ~a" name)))
|
||||
"The handler for the commfailure event.")
|
||||
(powerout
|
||||
(gexp
|
||||
#~(#t))
|
||||
"The handler for the powerout event.")
|
||||
(onbattery
|
||||
(gexp
|
||||
#~((let ((msg (format #f "~a UPS ~a Power Failure !!!"
|
||||
(gethostname) name)))
|
||||
(mail-to-root msg msg))
|
||||
(wall "Power failure on UPS ~a. Running on batteries." name)))
|
||||
"The handler for the onbattery event.")
|
||||
(offbattery
|
||||
(gexp
|
||||
#~((let ((msg (format #f "~a UPS ~a Power has returned."
|
||||
(gethostname) name)))
|
||||
(mail-to-root msg msg))
|
||||
(wall "Power has returned on UPS ~a..." name)))
|
||||
"The handler for the offbattery event.")
|
||||
(mainsback
|
||||
(gexp
|
||||
#~((when (file-exists? powerfail-file)
|
||||
(wall "Continuing with shutdown."))))
|
||||
"The handler for the mainsback event.")
|
||||
(failing
|
||||
(gexp
|
||||
#~((wall "Battery power exhausted on UPS ~a. Doing shutdown." name)))
|
||||
"The handler for the failing event.")
|
||||
(timeout
|
||||
(gexp
|
||||
#~((wall "Battery time limit exceeded on UPS ~a. Doing shutdown." name)))
|
||||
"The handler for the timeout event.")
|
||||
(loadlimit
|
||||
(gexp
|
||||
#~((wall "Remaining battery charge below limit on UPS ~a. Doing shutdown." name)))
|
||||
"The handler for the loadlimit event.")
|
||||
(runlimit
|
||||
(gexp
|
||||
#~((wall "Remaining battery runtime below limit on UPS ~a. Doing shutdown." name)))
|
||||
"The handler for the runlimit event.")
|
||||
(doreboot
|
||||
(gexp
|
||||
#~((wall "UPS ~a initiating Reboot Sequence" name)
|
||||
(system* #$(file-append shepherd "/sbin/reboot"))))
|
||||
"The handler for the doreboot event.")
|
||||
(doshutdown
|
||||
(gexp
|
||||
#~((wall "UPS ~a initiated Shutdown Sequence" name)
|
||||
(system* #$(file-append shepherd "/sbin/halt"))))
|
||||
"The handler for the doshutdown event.")
|
||||
(annoyme
|
||||
(gexp
|
||||
#~((wall "Power problems with UPS ~a. Please logoff." name)))
|
||||
"The handler for the annoyme event.")
|
||||
(emergency
|
||||
(gexp
|
||||
#~((wall "Emergency Shutdown. Possible battery failure on UPS ~a." name)))
|
||||
"The handler for the emergency event.")
|
||||
(changeme
|
||||
(gexp
|
||||
#~((let ((msg (format #f "~a UPS ~a battery needs changing NOW."
|
||||
(gethostname) name)))
|
||||
(mail-to-root msg msg))
|
||||
(wall "Emergency! Batteries have failed on UPS ~a. Change them NOW." name)))
|
||||
"The handler for the changeme event.")
|
||||
(remotedown
|
||||
(gexp
|
||||
#~((wall "Remote Shutdown. Beginning Shutdown Sequence.")))
|
||||
"The handler for the remotedown event.")
|
||||
(startselftest
|
||||
(gexp
|
||||
#~(#t))
|
||||
"The handler for the startselftest event.")
|
||||
(endselftest
|
||||
(gexp
|
||||
#~(#t))
|
||||
"The handler for the endselftest event.")
|
||||
(battdetach
|
||||
(gexp
|
||||
#~(#t))
|
||||
"The handler for the battdetach event.")
|
||||
(battattach
|
||||
(gexp
|
||||
#~(#t))
|
||||
"The handler for the battattach event."))
|
||||
|
||||
(define-syntax define-enum
|
||||
(lambda (x)
|
||||
(syntax-case x ()
|
||||
((_ name values)
|
||||
(let* ((datum/name (syntax->datum #'name))
|
||||
(datum/predicate (string->symbol
|
||||
(format #f "enum-~a?" datum/name)))
|
||||
(datum/serialize (string->symbol
|
||||
(format #f "serialize-enum-~a" datum/name))))
|
||||
(with-syntax
|
||||
((predicate (datum->syntax x datum/predicate))
|
||||
(serialize (datum->syntax x datum/serialize)))
|
||||
#'(begin
|
||||
(define (predicate value)
|
||||
(memq value values))
|
||||
(define serialize serialize-symbol))))))))
|
||||
|
||||
(define mangle-field-name
|
||||
(match-lambda
|
||||
('name "UPSNAME")
|
||||
('cable "UPSCABLE")
|
||||
('type "UPSTYPE")
|
||||
('device "DEVICE")
|
||||
('poll-time "POLLTIME")
|
||||
('lock-dir "LOCKFILE")
|
||||
('power-fail-dir "PWRFAILDIR")
|
||||
('no-login-dir "NOLOGINDIR")
|
||||
('on-batery-delay "ONBATTERYDELAY")
|
||||
('battery-level "BATTERYLEVEL")
|
||||
('remaining-minutes "MINUTES")
|
||||
('timeout "TIMEOUT")
|
||||
('annoy-interval "ANNOY")
|
||||
('annoy-delay "ANNOYDELAY")
|
||||
('no-logon "NOLOGON")
|
||||
('kill-delay "KILLDELAY")
|
||||
('net-server "NETSERVER")
|
||||
('net-server-ip "NISIP")
|
||||
('net-server-port "NISPORT")
|
||||
('net-server-events-file "EVENTSFILE")
|
||||
('net-server-events-file-max-size "EVENTSFILEMAX")
|
||||
('class "UPSCLASS")
|
||||
('mode "UPSMODE")
|
||||
('stat-time "STATTIME")
|
||||
('stat-file "STATFILE")
|
||||
('log-stats "LOGSTATS")
|
||||
('data-time "DATATIME")
|
||||
('facility "FACILITY")))
|
||||
|
||||
(define (serialize-string field-name value)
|
||||
#~(format #f "~a ~a\n" #$(mangle-field-name field-name) '#$value))
|
||||
(define serialize-symbol serialize-string)
|
||||
(define serialize-integer serialize-string)
|
||||
(define (serialize-boolean field-name value)
|
||||
#~(format #f "~a ~a\n"
|
||||
#$(mangle-field-name field-name)
|
||||
#$(if value "on" "off")))
|
||||
|
||||
(define-maybe string)
|
||||
|
||||
(define-enum cable '( simple smart ether usb
|
||||
940-0119A 940-0127A 940-0128A 940-0020B 940-0020C
|
||||
940-0023A 940-0024B 940-0024C 940-1524C 940-0024G
|
||||
940-0095A 940-0095B 940-0095C 940-0625A MAM-04-02-2000))
|
||||
(define-enum type '(apcsmart usb net snmp netsnmp dumb pcnet modbus test))
|
||||
(define-enum no-logon '(disable timeout percent minutes always))
|
||||
(define-enum class '(standalone shareslave sharemaster))
|
||||
(define-enum mode '(disable share))
|
||||
|
||||
(define-configuration apcupsd-configuration
|
||||
(apcupsd (package apcupsd) "The @code{apcupsd} package to use.")
|
||||
|
||||
(shepherd-service-name
|
||||
(symbol 'apcupsd)
|
||||
"The name of the shepherd service. You can add the service multiple times
|
||||
with different names to manage multiple UPSes."
|
||||
empty-serializer)
|
||||
(auto-start?
|
||||
(boolean #t)
|
||||
"Should the shepherd service auto-start?"
|
||||
empty-serializer)
|
||||
(pid-file
|
||||
(string "/run/apcupsd.pid")
|
||||
"The file name of the PID file."
|
||||
empty-serializer)
|
||||
(debug-level
|
||||
(integer 0)
|
||||
"The logging verbosity. Bigger number means more logs. The source code
|
||||
uses up to @code{300} as debug level value, so a value of @code{999} seems
|
||||
reasonable to enable all the logs."
|
||||
empty-serializer)
|
||||
|
||||
(run-dir
|
||||
(string "/run/apcupsd")
|
||||
"The directory containing runtime information. You need to change this if
|
||||
you desire to run multiple instances of the daemon."
|
||||
empty-serializer)
|
||||
|
||||
;; General configuration parameters
|
||||
(name
|
||||
maybe-string
|
||||
"Use this to give your UPS a name in log files and such. This is
|
||||
particularly useful if you have multiple UPSes. This does not set the EEPROM.
|
||||
It should be 8 characters or less.")
|
||||
(cable
|
||||
(enum-cable 'usb)
|
||||
"The type of a cable connecting the UPS to your computer. Possible generic
|
||||
choices are @code{'simple}, @code{'smart}, @code{'ether} and
|
||||
@code{'usb}.
|
||||
|
||||
Alternatively, a specific cable model number may be used: @code{'940-0119A},
|
||||
@code{'940-0127A}, @code{'940-0128A}, @code{'940-0020B}, @code{'940-0020C},
|
||||
@code{'940-0023A}, @code{'940-0024B}, @code{'940-0024C}, @code{'940-1524C},
|
||||
@code{'940-0024G}, @code{'940-0095A}, @code{'940-0095B}, @code{'940-0095C},
|
||||
@code{'940-0625A}, @code{'M-04-02-2000}.")
|
||||
(type
|
||||
(enum-type 'usb)
|
||||
"The type of the UPS you have.
|
||||
|
||||
@table @code
|
||||
@item apcsmart
|
||||
Newer serial character device, appropriate for SmartUPS models using a serial
|
||||
cable (not an USB).
|
||||
|
||||
@item usb
|
||||
Most new UPSes are an USB.
|
||||
|
||||
@item net
|
||||
Network link to a master apcupsd through apcupsd's Network Information Server.
|
||||
This is used if the UPS powering your computer is connected to a different
|
||||
computer for monitoring.
|
||||
|
||||
@item snmp
|
||||
SNMP network link to an SNMP-enabled UPS device.
|
||||
|
||||
@item netsnmp
|
||||
Same as the SNMP above but requires use of the net-snmp library. Unless you
|
||||
have a specific need for this old driver, you should use the @code{'snmp}
|
||||
instead.
|
||||
|
||||
@item dumb
|
||||
An old serial character device for use with simple-signaling UPSes.
|
||||
|
||||
@item pcnet
|
||||
A PowerChute Network Shutdown protocol which can be used as an alternative to
|
||||
an SNMP with the AP9617 family of smart slot cards.
|
||||
|
||||
@item modbus
|
||||
A serial device for use with newest SmartUPS models supporting the MODBUS
|
||||
protocol.
|
||||
|
||||
@end table")
|
||||
(device
|
||||
(string "")
|
||||
"For USB UPSes, usually you want to set this to an empty string (the
|
||||
default). For other UPS types, you must specify an appropriate port or
|
||||
address.
|
||||
|
||||
@table @code
|
||||
@item apcsmart
|
||||
Set to the appropriate @file{/dev/tty**} device.
|
||||
|
||||
@item usb
|
||||
A null string setting enables auto-detection, which is the best choice for
|
||||
most installations.
|
||||
|
||||
@item net
|
||||
Set to @code{@var{hostname}:@var{port}}.
|
||||
|
||||
@item snmp
|
||||
Set to @code{@var{hostname}:@var{port}:@var{vendor}:@var{community}}. The
|
||||
@var{hostname} is the ip address or hostname of the UPS on the network. The
|
||||
@var{vendor} can be can be \"APC\" or \"APC_NOTRAP\". \"APC_NOTRAP\" will
|
||||
disable SNMP trap catching; you usually want \"APC\". The @var{port} is
|
||||
usually 161. The @var{community} is usually \"private\".
|
||||
|
||||
@item netsnmp
|
||||
Same as the @code{'snmp}.
|
||||
|
||||
@item dumb
|
||||
Set to the appropriate @file{/dev/tty**} device.
|
||||
|
||||
@item pcnet
|
||||
Set to @code{@var{ipaddr}:@var{username}:@var{passphrase}:@var{port}}. The
|
||||
@var{ipaddr} is the IP address of the UPS management card. The @var{username}
|
||||
and the @var{passphrase} are the credentials for which the card has been
|
||||
configured. The @var{port} is the port number on which to listen for messages
|
||||
from the UPS, normally 3052. If this parameter is empty or missing, the
|
||||
default of 3052 will be used.
|
||||
|
||||
@item modbus
|
||||
Set to the appropriate @file{/dev/tty**} device. You can also leave it empty
|
||||
for MODBUS over USB or set to the serial number of the UPS.
|
||||
|
||||
@end table")
|
||||
(poll-time
|
||||
(integer 60)
|
||||
"The interval (in seconds) at which apcupsd polls the UPS for status. This
|
||||
setting applies both to directly-attached UPSes (apcsmart, usb, dumb) and
|
||||
networked UPSes (net, snmp). Lowering this setting will improve the apcupsd's
|
||||
responsiveness to certain events at the cost of higher CPU utilization.")
|
||||
|
||||
;; Configuration parameters used during power failures
|
||||
(on-batery-delay
|
||||
(integer 6)
|
||||
"The time in seconds from when a power failure is detected until we react
|
||||
to it with an onbattery event. The @code{'powerout} event will be triggered
|
||||
immediately when a power failure is detected. However, the @code{'onbattery}
|
||||
event will be trigger only after this delay.")
|
||||
(battery-level
|
||||
(integer 5)
|
||||
"If during a power failure, the remaining battery percentage (as reported
|
||||
by the UPS) is below or equal to this value, the apcupsd will initiate a
|
||||
system shutdown.
|
||||
|
||||
@quotation Note
|
||||
@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work
|
||||
in a conjunction, so the first that occurs will cause the initation of a
|
||||
shutdown.
|
||||
@end quotation")
|
||||
(remaining-minutes
|
||||
(integer 3)
|
||||
"If during a power failure, the remaining runtime in minutes (as calculated
|
||||
internally by the UPS) is below or equal to this value, apcupsd will initiate
|
||||
a system shutdown.
|
||||
|
||||
@quotation Note
|
||||
@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work
|
||||
in a conjunction, so the first that occurs will cause the initation of a
|
||||
shutdown.
|
||||
@end quotation")
|
||||
(timeout
|
||||
(integer 0)
|
||||
"If during a power failure, the UPS has run on batteries for this many
|
||||
seconds or longer, apcupsd will initiate a system shutdown. The value of 0
|
||||
disables this timer.
|
||||
|
||||
@quotation Note
|
||||
@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work
|
||||
in a conjunction, so the first that occurs will cause the initation of a
|
||||
shutdown.
|
||||
@end quotation")
|
||||
(annoy-interval
|
||||
(integer 300)
|
||||
"The time in seconds between annoying users (via the @code{'annoyme} event)
|
||||
to sign off prior to system shutdown. 0 disables.")
|
||||
(annoy-delay
|
||||
(integer 60)
|
||||
"The initial delay in seconds after a power failure before warning users to
|
||||
get off the system.")
|
||||
(no-logon
|
||||
(enum-no-logon 'disable)
|
||||
"The condition which determines when users are prevented from logging in
|
||||
during a power failure.")
|
||||
(kill-delay
|
||||
(integer 0)
|
||||
"If this is non-zero, the apcupsd will continue running after a shutdown
|
||||
has been requested, and after the specified time in seconds attempt to kill
|
||||
the power. This is for use on systems where apcupsd cannot regain control
|
||||
after a shutdown.")
|
||||
|
||||
;; Configuration statements for Network Information Server
|
||||
(net-server
|
||||
(boolean #f)
|
||||
"If enabled, a network information server process will be started.")
|
||||
(net-server-ip
|
||||
(string "127.0.0.1")
|
||||
"An IP address on which the NIS server will listen for incoming
|
||||
connections.")
|
||||
(net-server-port
|
||||
(integer 3551)
|
||||
"An IP port on which the NIS server will listen for incoming connections.")
|
||||
(net-server-events-file
|
||||
maybe-string
|
||||
"If you want the last few EVENTS to be available over the network by the
|
||||
network information server, you must set this to a file name.")
|
||||
(net-server-events-file-max-size
|
||||
(integer 10)
|
||||
"The maximum size of the events file in kilobytes.")
|
||||
;; Configuration statements used if sharing a UPS with more than one machine
|
||||
(class (enum-class 'standalone)
|
||||
"Normally standalone unless you share an UPS using an APC ShareUPS card.")
|
||||
(mode (enum-mode 'disable)
|
||||
"Normally disable unless you share an UPS using an APC ShareUPS card.")
|
||||
;; Configuration statements to control apcupsd system logging
|
||||
(stat-time
|
||||
(integer 0)
|
||||
"The time interval in seconds between writing the status file, 0
|
||||
disables.")
|
||||
(log-stats
|
||||
(boolean #f)
|
||||
"Also write the stats as a logs. This generates a lot of output.")
|
||||
(data-time
|
||||
(integer 0)
|
||||
"The time interval in seconds between writing the data records to the log
|
||||
file, 0 disables.")
|
||||
(facility
|
||||
maybe-string
|
||||
"The logging facility for the syslog.")
|
||||
|
||||
;; Event handlers
|
||||
(event-handlers
|
||||
(apcupsd-event-handlers (apcupsd-event-handlers))
|
||||
"Handlers for events produced by apcupsd."
|
||||
empty-serializer))
|
||||
|
||||
(define (%apccontrol config)
|
||||
(program-file
|
||||
"apccontrol"
|
||||
(match-record (apcupsd-configuration-event-handlers config)
|
||||
<apcupsd-event-handlers>
|
||||
( killpower commfailure commok powerout onbattery offbattery mainsback
|
||||
failing timeout loadlimit runlimit doreboot doshutdown annoyme
|
||||
emergency changeme remotedown startselftest endselftest battdetach
|
||||
battattach )
|
||||
#~(begin
|
||||
(use-modules (ice-9 format)
|
||||
(ice-9 match)
|
||||
(ice-9 popen)
|
||||
(srfi srfi-9)
|
||||
#$@(apcupsd-event-handlers-modules
|
||||
(apcupsd-configuration-event-handlers config)))
|
||||
;; Script dir depends on these, and the configuration depends on the
|
||||
;; script dir. To sever the cyclic dependency, pass the file names via
|
||||
;; environment variables.
|
||||
(define conf (getenv "GUIX_APCUPSD_CONF"))
|
||||
(define powerfail-file (getenv "GUIX_APCUPSD_POWERFAIL_FILE"))
|
||||
|
||||
(define (err . args)
|
||||
(apply format (current-error-port) args))
|
||||
(define (wall . args)
|
||||
(system* #$(file-append util-linux "/bin/wall") (apply format #f args)))
|
||||
(define (apcupsd . args)
|
||||
(apply system* #$(file-append apcupsd "/sbin/apcupsd") "-f" conf args))
|
||||
(define (mail-to-root subject body)
|
||||
(let ((port (open-pipe* OPEN_WRITE
|
||||
"/run/privileged/bin/sendmail"
|
||||
"-F" "apcupsd"
|
||||
"root")))
|
||||
(format port "Subject: ~a~%~%~a~&" subject body)
|
||||
(close-pipe port)))
|
||||
(match (cdr (command-line))
|
||||
(((? string? cmd) name connected powered)
|
||||
(let ((connected? (match connected
|
||||
("1" #t)
|
||||
("0" #f)))
|
||||
(powered? (match powered
|
||||
("1" #t)
|
||||
("0" #f))))
|
||||
(match cmd
|
||||
("killpower" #$killpower)
|
||||
("commfailure" #$commfailure)
|
||||
("commok" #$commok)
|
||||
("powerout" #$powerout)
|
||||
("onbattery" #$onbattery)
|
||||
("offbattery" #$offbattery)
|
||||
("mainsback" #$mainsback)
|
||||
("failing" #$failing)
|
||||
("timeout" #$timeout)
|
||||
("loadlimit" #$loadlimit)
|
||||
("runlimit" #$runlimit)
|
||||
("doreboot" #$doreboot)
|
||||
("doshutdown" #$doshutdown)
|
||||
("annoyme" #$annoyme)
|
||||
("emergency" #$emergency)
|
||||
("changeme" #$changeme)
|
||||
("remotedown" #$remotedown)
|
||||
("startselftest" #$startselftest)
|
||||
("endselftest" #$endselftest)
|
||||
("battdetach" #$battdetach)
|
||||
("battattach" #$battattach)
|
||||
(_
|
||||
(err "Unknown event: ~a~%" cmd)
|
||||
(err "Iff the event was emitted by apcupsd, this is a bug.~%")
|
||||
(err "Please report to bug-guix@gnu.org.~%")
|
||||
(exit #f)))))
|
||||
(args
|
||||
(err "Unknown arguments: ~a~%" args)
|
||||
(err "Iff the arguments were passed by apcupsd, this is a bug.~%")
|
||||
(err "Please report to bug-guix@gnu.org.~%")
|
||||
(exit #f)))))))
|
||||
|
||||
(define (apcupsd-script-dir config)
|
||||
(computed-file
|
||||
"apcupsd-script-dir"
|
||||
#~(begin
|
||||
(mkdir #$output)
|
||||
(chdir #$output)
|
||||
(symlink #$(%apccontrol config) "apccontrol"))))
|
||||
|
||||
(define (apcupsd-config-file config)
|
||||
(let ((run-dir (apcupsd-configuration-run-dir config)))
|
||||
(mixed-text-file
|
||||
"apcupsd.conf"
|
||||
"\
|
||||
## apcupsd.conf v1.1 ##
|
||||
#
|
||||
# for apcupsd - GNU Guix
|
||||
#
|
||||
# \"apcupsd\" POSIX config file (generated by apcupsd-service-type)
|
||||
"
|
||||
(serialize-configuration config apcupsd-configuration-fields)
|
||||
;; This one is confusing. The manual page states:
|
||||
;;
|
||||
;; > It must be changed when running more than one copy of apcupsd on the
|
||||
;; > same computer to control multiple UPSes.
|
||||
;;
|
||||
;; However would you not want the lock to be per-device, not per-process?
|
||||
;; I decided to follow the documentation, but I do not understand why it
|
||||
;; should be like this. I do not have multiple UPSes to try.
|
||||
(serialize-string 'lock-dir (string-append run-dir "/lock"))
|
||||
(serialize-string 'power-fail-dir run-dir)
|
||||
(serialize-string 'no-login-dir run-dir)
|
||||
(serialize-string 'stat-file (string-append run-dir "/apcupsd.status"))
|
||||
"SCRIPTDIR " (apcupsd-script-dir config) "\n")))
|
||||
|
||||
(define (apcupsd-activation config)
|
||||
(match-record config <apcupsd-configuration> (run-dir)
|
||||
#~(begin
|
||||
(use-modules (guix build utils))
|
||||
(mkdir-p #$(string-append run-dir "/lock")))))
|
||||
|
||||
(define (apcupsd-shepherd-services config)
|
||||
(match-record config <apcupsd-configuration>
|
||||
( apcupsd pid-file debug-level run-dir
|
||||
shepherd-service-name auto-start?)
|
||||
(let ((config-file (apcupsd-config-file config)))
|
||||
(list
|
||||
(shepherd-service
|
||||
(documentation "Run the apcupsd daemon.")
|
||||
(requirement '(user-processes))
|
||||
(provision (list shepherd-service-name))
|
||||
(auto-start? auto-start?)
|
||||
(start #~(make-forkexec-constructor
|
||||
'(#$(file-append apcupsd "/sbin/apcupsd")
|
||||
"-b" ;do not daemonize
|
||||
"-f" #$config-file
|
||||
"-P" #$pid-file
|
||||
"-d" #$(number->string debug-level))
|
||||
#:log-file
|
||||
#$(format #f "/var/log/~a.log" shepherd-service-name)
|
||||
#:environment-variables
|
||||
(cons* (string-append "GUIX_APCUPSD_CONF="
|
||||
#$config-file)
|
||||
#$(string-append "GUIX_APCUPSD_POWERFAIL_FILE="
|
||||
run-dir "/powerfail")
|
||||
(default-environment-variables))))
|
||||
(stop #~(make-kill-destructor))
|
||||
(actions (list (shepherd-configuration-action config-file))))))))
|
||||
|
||||
(define (apcupsd-pam-extensions config)
|
||||
;; The apcupsd can be configured to prevent users from logging in on certain
|
||||
;; conditions. This is implemented by creation of a "nologin" file, and
|
||||
;; using a pam nologin module to prevent the login (if the file exists).
|
||||
(define pam-nologin
|
||||
(pam-entry
|
||||
(control "required")
|
||||
(module "pam_nologin.so")
|
||||
(arguments (list (string-append "file="
|
||||
(apcupsd-configuration-run-dir config)
|
||||
"/nologin")))))
|
||||
|
||||
(list (pam-extension
|
||||
(transformer
|
||||
(lambda (pam)
|
||||
(pam-service
|
||||
(inherit pam)
|
||||
(auth (cons pam-nologin (pam-service-auth pam)))))))))
|
||||
|
||||
(define apcupsd-service-type
|
||||
(service-type
|
||||
(name 'apcupsd)
|
||||
(description "Configure and optionally start the apcupsd.")
|
||||
(extensions (list (service-extension activation-service-type
|
||||
apcupsd-activation)
|
||||
(service-extension shepherd-root-service-type
|
||||
apcupsd-shepherd-services)
|
||||
(service-extension pam-root-service-type
|
||||
apcupsd-pam-extensions)))
|
||||
(default-value (apcupsd-configuration))))
|